except the [On/Off] and [Shift]+[2] (Lock) keys, are locked. You can repress
[Shift]+[2] (Lock) to unlock the front panel.

5.3 Save and Recall Operations

The power supply can save up to 10 common parameters in nonvolatile memory
(No. 1 to No. 10) for user to recall conveniently. The saved settings include the
following parameters.
Category
Main interface
Config menu
Protect menu
You can do the save and recall operations by the following two methods.
Parameter
Voltage setting: Vs
Current setting: Is
Upper limit of voltage: Vh, and lower limit of voltage: Vl
Upper limit of current: I+, and lower limit of current: I-
Upper limit of power: P+, and lower limit of power: P-
The output status of the instrument: [On/Off]
CC/CV loop priority mode: Mode
CC/CV loop speed: Speed
Voltage/Current rise time: V-Rise Time/I-Rise Time
Voltage/Current fall time: V-Fall Time/I-Fall Time
On/Off switch delay: On Delay/Off Delay
Internal resistance of the power supply: Output Res
OCP/OVP/OPP/UCP/UVP switch status: On/Off
OCP/OVP/OPP/UCP/UVP limit setting: Level
OCP/OVP/OPP/UCP/UVP delay time: Delay
UCP/UVP warm-up time: Warm-up
Press the composite keys [Shift]+[+/-] (Save) to save the parameters. Press
the [Recall] key to recall the parameters.
SCPI commands: *SAV and *RCL