ITech IT6000C Series User Manual page 128

Bi-directional programmable dc power supply
Hide thumbs Also See for IT6000C Series:
Table of Contents

Advertisement

Configure the Function Menu
1. Press the composite button [Shift]+[1] (Log) on the front panel to enter the
2. Set the value of Sample Period and press [Enter].
3. Set the value of Duration and press [Enter].
configuration menu of the data logging function.
The parameters are described as follows:
Menu Item
Description
Sample
This parameter indicates the data
Period
sampling interval (unit: s), that is, the
test data is recorded once every X
seconds.
The input range supported by the in-
strument is: 0 - 9
Duration
This parameter indicates the time for
data recording (unit: s), namely, the
data recording will be completed in Y
seconds and be ready for the next
data record.
The input range supported by the in-
strument is: 0 - 3600
Source
This parameter indicates the source
of recorded data, including voltage
(V), current (I), voltage and current
(V/I).
Data Type
This parameter indicates the type of
recorded data, including:
Average: This is the default se-
lected data type, namely, the
average of all data acquired in the
data recording period as indicated
in the table of saved data.
Max/Min: If this option is se-
lected, it means the maximum
value and minimum value of data
acquired in the data recording pe-
riod as indicated in the data sav-
ing table.
Copyright © Itech Electronic Co., Ltd.
Basic Operation
Setting
Set the value by in-
putting the value
through the number
key or rotating the
knob.
Use the Left and
Right arrow key or
the rotation knob to
select.
116

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IT6000C Series and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF