t: Time
•
U: Test voltage
•
t
: Duration of pulse
d
•
t
: Rising Slope
r
•
U
: The supply voltage of the generator in operation: U
A
system, U
= 28V in the 24V system. (see ISO 16750-1)
A
•
U
: Peak voltage
S
Parameter
U
S a
(V)
79≤U
Ri
a
(Ω)
0.5≤Ri≤4
t
(ms)
40≤t
d
t
(ms)
–
r
a
If not otherwise agreed, use the upper voltage level with the upper value for
internal resistance or use the lower voltage level with the lower value for in-
ternal resistance.
The pulse shape and parameters for an alternator with centralized load dump
suppression (Test B) are given in follow.
Copyright © Itech Electronic Co., Ltd.
Type of system
12V
24V
≤101
151≤U
S
S
1≤Ri≤8
≤400
100≤t
d
d
–
Power Supply Function
= 14V in the 12V
A
Minimum test
requirements
≤202
10 pulses at 1 min intervals
≤350
81