6.1.3.3 IT6018C-500-120
Rated value
( 0 ℃-40 ℃)
Line Regulation
Load Regulation
Setup Resolution
Read Back Resolution
Setup Accuracy
( within 12 months, 25℃
±5℃)
±(%of Output+Offset)
Read Back Accuracy
( within 12 months, 25℃
±5℃)
±(%of Output+Offset)
Ripple
(20Hz -20MHz)
Setup Temperature
Coefficient
(%of Output/℃+Offset)
Parameter
Output Voltage
Output Current
Output Power
Output Resistance
Voltage
Current
Voltage
Current
Voltage
Current
Power
Resistance
Voltage
Current
Power
Resistance
Voltage
Current
Power
Resistance
Voltage
Current
Power
Resistance
Voltage
Current
Voltage
Current
Copyright © Itech Electronic Co., Ltd.
Technical Specification
IT6018C-500-120
0~500V
-120~120A
-18000~18000W
0~1Ω
≤0.01%FS
≤0.05%FS
≤0.02%FS
≤0.05%FS
0.01V
0.01A
0.001kW
0.01Ω
0.01V
0.01A
0.001kW
0.01Ω
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
≤0.5% + 0.5%FS
≤1% + 1%FS
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
≤0.5% + 0.5%FS
≤1% + 1%FS
≤200mVpp(MAX:500mVpp)
≤0.1%FS RMS
≤50PPM/℃
≤200PPM/℃
175