To configure a C304 as a Form-C relay, the two break-off tabs shown must be broken off of the module. Use
a pair of needle-nose pliers to break off each tab.
Caution:
Caution:
Caution: Failure to break tabs when configuring for Form-C Relay operation can cause damage to the C304
Caution:
Caution:
module.
COMMUNICATIONS LOOP CONNECTIONS
COMMUNICATIONS LOOP CONNECTIONS
COMMUNICATIONS LOOP CONNECTIONS
COMMUNICATIONS LOOP CONNECTIONS
COMMUNICATIONS LOOP CONNECTIONS
Connect the MS-9200 Communications SLC Loop to C304 Terminals 1(-) and 2(+). The C304 occupies one
module address on the Loop. Set the rotary switches on the module to the particular Loop address required.
CONTACT CONNECTIONS
CONTACT CONNECTIONS
CONTACT CONNECTIONS
CONTACT CONNECTIONS
CONTACT CONNECTIONS
Wire the common and the normally-open or normally-closed contacts to the module as needed.
CONTACT RATINGS
CONTACT RATINGS
CONTACT RATINGS
CONTACT RATINGS
CONTACT RATINGS
Resistive: 2 Amps @ 30 VDC*
Inductive:
1 Amp @ 30 VDC (0.6 PF)
Pilot Duty: 0.6 Amps @30 VDC (0.35 PF)
0.3 Amps @ 110 VDC (0.35 PF)
0.3 Amps @ 120 VAC (0.35 PF)
*Certain electromechanical devices exhibit inductive loading characteristics. For these types of devices, derate the outputs to
1 Amp. Refer to the Device Compatibility document for load characteristics by device.
38
Technical Manuals Online! - http://www.tech-man.com
A+
B - A-
3
4
5
6
Break-off Tabs
Normally-Open
Normally-Open
Normally-Open
Normally-Open
Normally-Open
Contact
Contact
Contact
Contact
Contact
Document # 50428
firealarmresources.com
+ To next Device
- on Loop
C304
C304
C304
C304
C304
Common Contact
Common Contact
Common Contact
Common Contact
Common Contact
Normally-Closed Contact
Normally-Closed Contact
Normally-Closed Contact
Normally-Closed Contact
Normally-Closed Contact
Rev. B1
7/28/97
P/N 50428:B1
CAUTION!
CAUTION!
CAUTION! Do not loop
CAUTION!
CAUTION!
wiring under any terminals.
Break wire run to maintain
supervision.