Battery Charging System - Ducati Monster 696 2009 Manual

Table of Contents

Advertisement

P
section
P 2

2 - Battery charging system

A
Checking the battery charging system
To check the current flow in the charging circuit, use the "DDS" tester, which is equipped with an inductive clamp-type ammeter.
Follow the instructions given in the paragraph "Testing the battery charging system" (Sect. D 5).
A negative value means that charging system is not powering the loads and a significant amount of current must be supplied by
B
the battery, which is discharging at the time of the measurement.
Alternatively, you can use a multimeter (Sect. P 9, Diagnostic instruments): connect the multimeter probes to the battery
terminals, select the DC scale on the instrument and check for the presence of 14.5 V ±0.5 at an engine speed of 3000 rpm.
Important
C
If polarity is reversed when clamping the ammeter onto the cable, the sign of the readings will also be reversed, giving rise to
incorrect diagnosis.
D
E
F
G
H
L
M
N
P
36
Electrical system
Monster 696/696+ - M.Y. 2009 - edition 00