Id Code - ProMinent DULCOMETER Assembly And Operating Instructions Manual

Multi-parameter controller
Table of Contents

Advertisement

3

ID Code

Device identification / identity code
DULCOMETER
, Multi-parameter Controller diaLog DACa
®
D
Version
A
C
a
00 With ProMinent
S0 With fitting kit for control cabinet
Operating voltage
6 90 ... 253 V, 48/63 Hz
Channel 1*
1 Measurement + control, 2 pumps, 2 control inputs, 2 mA outputs
Channel 2**
0 No second channel
2 Package 2: Disturbance variable (mA) or external remote setpoint
3 Package 3: 2nd measurement + control, additionally 2 pumps, addi‐
4 Package 4: 2nd measurement + control, additionally 2 pumps, addi‐
®
Logo
via mA or pH compensation for chlorine (all acting on channel 1)
tionally 3 control inputs
tionally 3 control inputs, disturbance variable (mA or frequency), pH
compensation for chlorine
Software default settings
0
no default settings
1
Batch neutralisation 2 x pH measurement with 1-2-way con‐
troller and final inspection
2
Flow neutralisation 2 x pH measurement with 1-2-way con‐
troller, disturbance variable and final inspection
3
pH-/ORP measurement/control (pH 2 page, ORP 1-way)
4
pH-/Cl
measurement/control (pH 2-way, chlorine 1-way)
2
ID Code
15