1
Device Identification / Identity Code
D1C A
DULCOMETER
®
Type of mounting
D
Control panel installation 96 x 96 mm (IP 54)
W
Wall mounting (IP 65)
Operating voltage
0
230 V 50/60 Hz
1
115 V 50/60 Hz
2
200 V 50/60 Hz (only with control panel installation)
3
100 V 50/60 Hz (only with control panel installation)
4
24 V AC/DC
C
D1C A
2
Controller Series D1C / Version A
Measured variable
Chlorine (0-0.5/2/5/10/20/50/100 ppm)
Connection of measured variable
1
Terminal, standard signal 0/4-20 mA
Correction variable
0
None
1
pH for chlorine via standard signal 0/4-20 mA
Feed forward control
0
None
1
Flow as standard signal 0/4-20 mA
2
Flow as frequency 0-500 Hz
3
Flow as frequency 0-10 Hz
Please enter the identity code of your device here!
Control input
0
None
1
Pause
Signal output
0
None
1
Standard signal 0/4-20 mA measured value
2
Standard signal 0/4-20 mA control variable
3
Standard signal 0/4-20 mA correcting variable
4
2 standard signal 0/4-20 mA outputs, freely programmable
Power control
G
Alarm and 2 limit value/timer relays
M
Alarm and 2 solenoid valve relays
R
Alarm relay and servomotor with feedback
0
2
Pump control
None
Two pumps
Control characteristic
0
None
1
Proportional control
2
PID control
Log output
0
None
Language
D
German
E
English
F
French
I
Italian
N
Dutch
S
Spanish
P
Polish
A
Swedish
B
Portuguese
U
Hungarian
G
Czech
Need help?
Do you have a question about the DULCOMETER D1C and is the answer not in the manual?