STARTER SOLENOID BENCH TEST

Test the start solenoid by powering the solenoid using
battery voltage for a maximum of 5 seconds. With the
solenoid energized, resistance should read about 0 - 0.5
Ohms between terminals (A) and (B). If resistance
measurement is out of specification, replace the starter
solenoid.
9926813 R04 - 2013-2016 RZR 570 Service Manual
© Copyright Polaris Industries Inc.

STARTER SOLENOID OPERATION

To energize the Starter Solenoid the following must
occur:
• The brake must be applied to provide a ground path
via the Orange wire.
• The key switch must be turned to the "start" position to
provide 12V power via the Green / White wire.
• Once the pull-in coil is energized, the solenoid pro-
vides a current path for 12V power to reach the starter
motor.