Quick Start-Up - Thermo Scientific MaxQ SHKE8000 Series Operating And Maintenance Manual

Stackable orbital shakers
Hide thumbs Also See for MaxQ SHKE8000 Series:
Table of Contents

Advertisement

Quick Start-Up

Thermo Scientific
Caution If the unit is shipped or stored in very cold conditions, allow the
unit to warm to ambient temperatures before using.
Caution This unit should be operated by trained personnel only, as
described in this manual. All appropriate personal protective equipment
should be worn as required.
At power-up, one of the the screens at right will
appear on the display for 10 seconds (where
X.XX is the current software revision) before it
shows the Actual and Setpoint times, speeds and
temperatures similar to those illustrated in Figure
2-2. For convenience, this is called the
Operating Screen throughout this manual.
Initially, the Actual values along the top of the liquid crystal display will
differ from the Setpoint values shown along the bottom. The Actual
numbers will change as the unit continues to operate.
Time - With the time set at Hold, the time showing in the upper left
portion of the LCD will begin to count upward, showing the total oper-
ating hours and minutes. The system will reset to 00:00 whenever the
unit is stopped and restarted, using the Stop and START buttons. The
system will not reset if the unit is turned off and on using the power
switch, or if the shaker door is repeatedly opened and closed.
Speed - The speed shown in the upper center portion of the LCD will
indicate the present platform speed. It will display zero RPM at rest and
will gradually rise to the setpoint speed after the START button is
pressed and the platform begins to rotate.
Temperature - The temperature shown in the upper right portion of the
LCD will indicate the ambient temperature inside the shaker and will
gradually move toward the setpoint value.
The values shown in Figure 2-2 are factory default settings. Other factory
settings are shown in the table below.
Table 2-1. Factory Default Settings
Function
Audible Alarm
RPM Tracking Limit (fixed)
Temp Tracking Limit
Over Temp Shutdown
Under Temp Shutdown
All Remote Alarms
Defrost
s
Default SHKE8000 & SHKE8000-1CE
ON
5 RPM
10°C
63°C - 65°C
N/A
ON
N/A
s
Software Version #
443 / 444 / 445 REL X.XX
SHKE8000 & SHKE8000-1CE
Software Version #
493 / 495 / 496 REL X.XX
SHKE8000-7 & SHKE8000-8CE
Default SHKE8000-7 & SHKE8000-8CE
ON
5 RPM
10°C
-1°C to +2°C
ON
ON, 12°C
MaxQ SHKE8000 Series Shakers
Section 2
Operation