Set the Undertemperature Alarm
2-14
MaxQ SHKE8000 Series Shakers
The Undertemperature alarm (Model SHKE8000-7 & SHKE8000-8CE)
activates whenever the operating temperature drops below the
Undertemperature setpoint by a few tenths of a °C. This adjustable limit is
set at the factory at approximately -1°C. To change this value, open the
Configuration menu by pressing the down
arrow, up arrow, and the Silence button,
and then the down arrow once again, in
the sequence shown at right.
Then press the Temperature
button beneath Alarms.
To change the Undertemperature
alarm setting, press the Speed
button beneath Under.
The following screen appears and
the present Undertemperature
alarm setting flashes.
Change the Temperature setting by pressing the up or down arrow. When
set, press any of the three buttons (Time, Speed, or Temp) to save the new
setpoint value and return to the previous screen, or press nothing for about
15 seconds to save the new setpoint value and return to the Operating
Screen.
Note The Undertemp Alarm setpoint values are calculated from the
hardware and will not include every numerical value between the upper
and lower limits.