HGM7110DC controller's rear as following:
Description of terminal connection:
NO.
Functions
1
DC Input -Ve
2
DC Input +Ve
3
Emergency Stop
4
Fuel (16A)
5
Crank (16A)
6
Aux. Output 1
7
Aux. Output 5
8
Aux. Output 6
9
GND
10
PWMOUT
11
Charger (D+)
12
Aux. Output 2
13
HGM7110DC Genset Controller
Cable
Remark
Size
2
2.5mm
Connected with negative of starter battery.
Connected with positive of starter battery. If wire
2
2.5mm
length is over 30m, better to double wires in
parallel. Max. 20A fuse is recommended.
2
2.5mm
Connected with +Ve via emergency stop button.
2
1.5mm
+Ve is supplied by terminal 3, rated 16A
+Ve is supplied by
2
1.5mm
terminal 3, rated 16A
2
1.5mm
+Ve is supplied by
2
1.5mm
terminal 2, rated 7A
2
1.5mm
2
1.5mm
Connect to PWM.
2
1.5mm
Connected with charger's D+ (WL) terminals. Be
2
1.0mm
hanging in the air If there is no this terminal.
Normally
2
1.5mm
outputs, rated 7A
Public points of relay
Version: 1.0
HGM7110DC Genset Controller
Connected to starter coil
Details see form 2
close
Details see form 2
2014-09-27