DGS-3130 Series Layer 3 Stackable Managed Switch Web UI Reference Guide
Parameter
Priority
Legacy Support
Mode
Max Wattage
Time Range
Click the Apply button to accept the changes made.
Click the Delete Time Range button remove the time range association for the entry.

PD Alive

This window is used to display and configure the PoE PD alive settings. The PoE alive feature provides the solution
when PD devices stop working or are not responding using the ping mechanism.
To view the following window, click System > PoE > PD Alive, as shown below:
The fields that can be configured for PD Alive Configuration are described below:
Parameter
Unit
From Port - To Port
Description
Select the priority for provisioning power to the port. Options to choose from are
Critical, High and Low.
Select this option to enable or disable the support of legacy PD.
Select the power management mode for the PoE ports. Options to choose from
are Auto and Never.
When selecting Auto in the Mode drop-down list, this option appears. Tick the
check box and enter the maximum wattage of power that can be provisioned to
the auto-detected PD. If the value is not entered, the class of the PD
automatically determines the maximum wattage which can be provisioned. The
valid range for maximum wattage is between 1000 mW and 30000 mW.
When selecting Auto in the Mode drop-down list, this option appears. Tick the
check box and enter the name of the time range to determine the activation
period.
Figure 3-145 PD Alive Window
Description
Select the stacking unit ID of the Switch that will be configured here.
Select the appropriate port range used for the configuration here.