Time Profile
Click the Delete Time Profile button to clear the setting in the corresponding Time Range field.
Click the Apply button to accept the changes made.

PD Alive

This window is used to configure the PD Alive function for PDs connected to the PoE ports. The ping
function is used to check if PDs, connected to the PoE ports, are active or not. When PDs appear to be
inactive, the specified action (Reset, Notify, or Both) will be taken.
View the following window, click System > PoE > PD Alive, as shown below:
The fields that can be configured are described below:
Parameter
From Port / To Port
PD Alive State
PD IP Address
Poll Interval
Retry Count
Waiting Time
Action
Click the Apply button to accept the changes made.
DIS-200G Series Industrial Gigabit Ethernet Smart Managed Switch
Select the name of the time range to determine the activation
period.
Description
Select the appropriate port range used for the configuration here.
Select to enable or disable the PD Alive function on the specified
port(s).
Enter the IP address of the PD here.
Enter the poll interval here. This is the interval between ping
messages from the system to PDs connected to the PoE port(s).
The range is from 10 to 300 seconds.
Enter the retry count here. This is the amount of ping messages
that will be sent (at each interval) when PDs are not responding.
The range is from 0 to 5.
Enter the waiting time here. This is how long the system will wait
before sending ping messages to the PD connected to the PoE
port after a 'Reset' action was taken. The range is from 30 to 300
seconds.
Select the action that will be taken here. Options to choose from
are Reset, Notify, and Both.
Reset - Specifies to reset the PoE port state (turn PoE off and on).
Notify - Specifies to send logs and traps to notify the administrator.
Both - Specifies to send logs and traps to notify the administrator
and to reset the PoE port state (turn PoE off and on).