DGS-3130 Series Layer 3 Stackable Managed Switch Web UI Reference Guide
The fields that can be configured are described below:
Parameter
Minimum Version
Fast Leave
Report Suppression
Suppression Time
Proxy Reporting
Source Address
Mrouter Port Learning
Querier State
Query Version
Query Interval
Max Response Time
Robustness Value
Last Listener Query Interval
Rate Limit
Ignore Topology Change
Click the Apply button to accept the changes made.
MLD Snooping Groups Settings
This window is used to display and configure the MLD snooping static group, and view MLD snooping group.
Description
Select the minimum version of MLD hosts that is allowed on the VLAN. Options
to choose from are 1 and 2.
Select this option to enable or disable the MLD snooping Fast Leave function. If
enabled, the membership is immediately removed when the system receives
the MLD leave message.
Select this option to enable or disable the report suppression.
Enter the interval of suppressing duplicate MLD reports or leaves. The range is
from 1 to 300.
Select this option to enable or disable the proxy-reporting function.
Enter the source IP of proxy reporting. This is available when Enabled is
selected in Proxy Reporting.
Select this option to enable or disable Mrouter port learning.
Select this option to enable or disable the querier state.
Select the general query packet version sent by the MLD snooping querier.
Options to choose from are 1, and 2.
Enter the interval at which the MLD snooping querier sends MLD general query
messages periodically. The range is from 1 to 31744.
Enter the maximum response time, in seconds, advertised in MLD snooping
queries. The range is from 1 to 25.
Enter the robustness variable used in MLD snooping. The range is from 1 to 7.
Enter the interval at which the MLD snooping querier sends MLD group-specific
or group-source-specific (channel) query messages. The range is from 1 to 25.
Enter the rate limit value here. The range is from 1 to 1000. Tick the No Limit
option to apply no rate limit on this profile.
Select to enable or disable the Ignore Topology Change feature here.