Double Chamber - Vacuum Packaging Machines VC999 K12/K12N/K12A/K12NA
Maintenance
13.3.5.3 Vacuum filter: Replace filter cartridge
Disconnect the machine from the power supply according to the description under "Maintenance
work on the power supply".
Open the electric cabinet with the supplied triangular socket spanner.
Open the vacuum filter (1) via a quarter turn.
Remove and dispose of the soiled filter cartridge (2).
Insert a new filter cartridge (3).
Close the vacuum filter and the electric cabinet.
2013-12-17
Fig. 13/11
Art. no. 520.454
Fig. 13/12
Page 59/91