Double Chamber - Vacuum Packaging Machines VC999 K12/K12N/K12A/K12NA
Description of the machine
3.2.2
Weight
Weight VC999 K12 and VC999 K12N
Weight VC999 K12A and VC999 K12NA
3.2.3
Vacuum technology
3.2.3.1
Vacuum pumps
Pump output
Max. vacuum
Cycle rate
Max. oil capacity
Optional: Machine with automatic chamber closing (VC999 K12A, VC999 K12NA types):
Vacuum pump
Pump output
Max. vacuum
Max. oil capacity
3.2.3.2
Vacuum generation
Vacuuming through to evaporation
Vacuuming through to the setpoint
Vacuuming in steps through to the setpoint
Standby vacuuming
Preventilation (Soft air) : Has a gentle effect on products and bags, prevents creases forming.
Intermediate ventilation: Prevents steam bubbles forming in the case of moist products.
3.2.4
Sealing technology
Separate double hot-wire sealing to trim off bag off-cuts.
3.2.5
Inert gas connection
There is only an inert gas connection on the VC999 K12N and VC999 K12NA machines.
The connection at the input valve for the tube measures øi 7 mm.
The requisite gas pressure is approx. 2 bar.
NOTICE
In line with international regulations, high-pressure gases may only be fed via a reducer valve !
2013-12-17
approx. 776 kg
approx. 827 kg
205 m
1 mbar
2-3 packaging cycles / min.
5 litres
20 m
1 mbar
0,4 liters
Art. no. 520.454
3
/h
3
3
/h at 50Hz, 24 m
/h at 60Hz
Page 20/91