Pneumatics (Vc999 K12A, Vc999 K12Na Types); Power Supply; Controller; Noise Emission - vc999 K12 Translation Of The Original Operating Manual

Double chamber - vacuum packaging machines
Table of Contents

Advertisement

Double Chamber - Vacuum Packaging Machines VC999 K12/K12N/K12A/K12NA
Description of the machine
3.2.6

Pneumatics (VC999 K12A, VC999 K12NA types)

Inlet pressure
Operating pressure
Connection size
Compressed air consumption
Quality of compressed air
Moisture content
3.2.7

Power supply

Equipment conforming to EN 60204-1.
The electrical connections depend on the customer's local power supply. Comply with the characteristic
data on the rating plate, which is attached to the back of the machine.
The circuit diagrams are contained in the section entitled "Diagrams" and in the electrical cabinets on
the machine.
3.2.8

Controller

Microcontroller
7-segment LED displays
Memory capacity each chamber:
3.2.9

Noise emission

Equivalent continuous noise level L
The test was conducted according to DIN EN ISO 11204; accuracy class 2, measurement
uncertainty +/- 2.5 dB.
2013-12-17
6 bar
4 bar
Pneumatic servicing unit
with nipple for flexible hose ø
or R ¼" for tube
4 NL/cycle/vacuum chamber
(VC999 K12A, VC999 K12NA)
dry
max. 6 g/m3 (water)
20 vacuum programs P-01 to P-20, with a write-
protect function
Program P-00 for test runs, cannot be write-
protected.
[dB]: 71,7
pA
Art. no. 520.454
9 mm
i
Page 21/91

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

K12nK12aK12na