Controls; Control Panel - vc999 K12 Translation Of The Original Operating Manual

Double chamber - vacuum packaging machines
Table of Contents

Advertisement

Double Chamber - Vacuum Packaging Machines VC999 K12/K12N/K12A/K12NA
Operation
9.4

Controls

9.4.1

Control panel

Controls
No. Symbol
1
2
3
4
5
6
7
8
2013-12-17
Name
Function
LED display 1
Displays the set value or the setting.
UP arrow button
Raises the value shown on LED display 1 or changes to
other possible settings.
Vacuum
The possible settings for the vacuum are called up in
succession.
If you press this button during programming, this leads to
the next parameter.
Intermediate
Length of the intermediate ventilation
ventilation
The time can be set to between 0.0 and 1.0 second(s).
UP arrow button
Packaging program:
Select the requested program number, ascending.
Service program:
Select parameter levels S-01, S-02, S-03 ..... in ascending
order. The parameter levels are displayed on LED display
2.
LED display 2
Packaging program:
Displays the number of the selected program.
Service program:
Displays the selected parameter level, S-01, S-02 etc. The
meanings of each of the levels are described in the
section on the "Service program".
The setting depends on the pressure. (‰)
Vacuum display
Time display
The setting depends on the time. (sec.)
Art. no. 520.454
Fig. 9/7