Program Overview - vc999 K12 Translation Of The Original Operating Manual

Double chamber - vacuum packaging machines
Table of Contents

Advertisement

Double Chamber - Vacuum Packaging Machines VC999 K12/K12N/K12A/K12NA
Operation
9.5.4

Program overview

The procedure for compiling or changing a program is outlined in the table below. You do not have to
adhere to this order, although it is recommended for checking that the procedure is complete.
Function button Function
* Arrow keys, see previous section on "Compiling or changing a program ", field D.
** Can be switched on and off in the service program.
2013-12-17
Select vacuuming mode
The vacuuming modes are described in the section
on the "Meaning of the parameters".
Vacuuming to evaporation point A
Vacuum setpoint
Evaporation sensitivity
Vacuuming to setpoint B
Vacuum setpoint
Vacuuming in stages to setpoint C **
Vacuum setpoint
Vacuum stage
Vacuum stop time
Inert gas **
Intermediate ventilation
Sealing
Cutting
Preventilation (Soft air)
Return to the basic setting
Is possible from any function.
Art. no. 520.454
Select settings
with the arrow buttons*
or
A, B, C
400 ... 999 ‰
0.5 ... 10.0 seconds
400 ... 999 ‰
400 ... 999 ‰
50 ... 499 ‰
0 ... 200 seconds
400 ... 999 ‰
999 ‰ = no inert gas
0.0 ... 1.0 second(s)
0.0 ... 5.0 second(s)
0.0 ... 5.0 second(s)
400 ... 999 ‰
999 ‰ = no preventilation
Page 44/91

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

K12nK12aK12na

Table of Contents