Performance Specifications - Basler L800k User Manual

Table of Contents

Advertisement

1.3 Performance Specifications

Specifications
Sensor
Number of Pixels
Pixel Size
Fill Factor
Spectral Response
Camera Link
Pixel Clock Speed
Maximum Data Rate
Maximum Line Rate
Minimum Line Rate
Video Output Type
Video Data Output
Modes
Synchronization
Exposure Time Control
Gain and Offset
Connectors
Power Requirements
Lens Adapters
Housing Size
(L x W x H)
Weight
Conformity
Table 1-2: Performance Specifications
BASLER L800
k
Draft
L801
k
Kodak KLI-4104 Linear CCD
8160
5.0 µm x 5.0 µm (5.0 µm pitch)
100%
350 nm to 1050 nm, peak at 660 nm (See Figure 1-2)
20 MHz
37 MPixels/s
4.7 kHz*
*when used with dual tap and dual separated tap
10 Hz in free-run
No minimum when an ExSync signal is used
(For proper operation, exposure time should not be less than 10% of the line
period.)
Camera Link LVDS - Base configuration
RS-644 LVDS when used with an optional Basler Interface
Converter (k-BIC)
Single tap (one pixel per clock cycle),
Dual tap (two pixels per clock cycle)
Dual separated tap (two pixels per clock cycle)
Selectable 10 or 8 bit depth
Via external ExSync signal or free-run
Edge-controlled, level-controlled, or programmable
Programmable via a serial link
One, 26-pin, female MDR connector
One, 6-pin, Hirose micro-miniature receptacle
12 VDC ± 10%
Max 5.0 W @ 12 VDC
F-mount
without lens adapter:
41.3 mm x 71 mm x 71 mm
with F-mount adapter: 79.1 mm x 71 mm x 71 mm
without lens adapter:
~ 310 g
with F-mount adapter: ~ 420 g
CE, FCC
L802
k
40 MHz
75 MPixels/s
9.4 kHz*
12 VDC ± 10%
Max 6.0 W @ 12 VDC
Introduction
L803
k
60 MHz
112 MPixels/s
14.1 kHz*
12 VDC ± 10%
Max 7.0 W @ 12 VDC
1-3

Advertisement

Table of Contents
loading

Table of Contents