Product ID Inquiry

Register Base Address: 0x0300
Field Name: Register Status
Description: The integer value in this field indicates the status of this inquiry register:
Field Name: Product ID
Description: String containing the camera's product ID number. The string is zero terminated if less than

Serial Number Inquiry

Register Base Address: 0x0400
Field Name: Register Status
Description: The integer value in this field indicates the status of this inquiry register:
Field Name: Serial Number
Description: String containing the camera's serial number. The string is zero terminated if less than 20

Camera Version Inquiry

Register Base Address: 0x0500
Field Name: Register Status
Description: The integer value in this field indicates the status of this inquiry register:
Field Name: Camera Version
Description: The value in this field indicates the camera's version information. The bytes in the field are
BASLER L800
k
0x00 = The register is not available
0x01 = The register is available.
20 bytes are needed and unterminated if all 20 bytes are needed.
0x00 = The register is not available
0x01 = The register is available.
bytes are needed and unterminated if all 20 bytes are needed.
0x00 = The register is not available
0x01 = The register is available.
interpreted as follows:
Byte 1 = Low byte of the camera version (BCD coded)
Byte 2 = High byte of the camera version (BCD coded)
Byte 3 = Register layout ID (BCD coded)
Draft
Offset: 0x0000
Offset: 0x0001
Offset: 0x0000
Offset: 0x0001
Offset: 0x0000
Offset: 0x0001
Configuring the Camera
Size: 1 Byte
Type: Read only
Size: 20 Bytes
Type: Read only
Size: 1 Byte
Type: Read only
Size: 20 Bytes
Type: Read only
Size: 1 Byte
Type: Read only
Size: 3 Bytes