Field Name: Raw Min
Description: Minimum allowed integer value for the raw line period setting.
Field Name: Raw Max
Description: Maximum allowed integer value for the raw line period setting.

Video Data Output Mode CSR

Register Base Address: 0x1700
Field Name: Register Status
Description: The integer value in this field indicates the status of this control register:
Field Name: Mode
Description: Writing an integer value to this field sets the video data output mode:
BASLER L800
k
The 4 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the min value
Byte 2 = Mid byte of the min value
Byte 3 = High byte of the min value
Byte 4 = Always 0x00 (not used)
The 4 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the max value
Byte 2 = Mid byte of the max value
Byte 3 = High byte of the max value
Byte 4 = Always 0x00 (not used)
0x00 = The register is not available
0x01 = The register is available. All related settings are OK
0x80 = A value in the register is set out of range
0x00 = Single 8 bit output
0x01 = Dual 8 bit output
0x02 = Single 10 bit output
0x03 = Dual 10 bit output
0x21 = Dual separated 8 bit output
0x23 = Dual separated 10 bit output
See Section
2.5.5
for a description of the video data output modes.
Draft
Offset: 0x0011
Offset: 0x0015
Offset: 0x0000
Offset: 0x0001
Configuring the Camera
Size: 4 Bytes Type: Read only
Size: 4 Bytes Type: Read only
Size: 1 Byte
Type: Read only
Size: 1 Byte
Type: Read / Write