Configuring the Camera

Test Image Mode CSR

Register Base Address: 0x1800
Field Name: Register Status
Description: The integer value in this field indicates the status of this control register:
Field Name: Mode
Description: Writing an integer value to this field sets the test image mode:

Camera Reset CSR

Register Base Address: 0x0B00
Field Name: Register Status
Description: The integer value in this field indicates the status of this control register:
Field Name: Reset
Description: Writing an integer value of 1 (0x01) to this field will initiate a camera reset. The reset be-
4-42
0x00 = The register is not available
0x01 = The register is available. All related settings are OK
0x80 = A value in the register is set out of range
0x00 = Test images off
0x01 = Test image 1 enabled (fixed gradient pattern)
0x02 = Test image 2 enabled (moving gradient pattern)
0x03 = Test image 3 enabled (uniform black pattern)
0x04 = Test image 4 enabled (uniform gray pattern)
See Section
3.10
for more information about test images.
0x00 = The register is not available
0x01 = The register is available. All related settings are OK
0x80 = A value in the register is set out of range
havior is similar to a power up reset.
Draft
Offset: 0x0000
Offset: 0x0001
Offset: 0x0000
Offset: 0x0001
Size: 1 Byte
Type: Read only
Size: 1 Byte
Type: Read / Write
Size: 1 Byte
Type: Read only
Size: 1 Byte
Type: Write only