Setting The Aoi - Basler L800k User Manual

Table of Contents

Advertisement

Figure 3-11: AOI Output on an L800k

3.7.1 Setting the AOI

You can set the AOI with the Camera Configuration Tool Plus (CCT+) or by using binary write
commands from within your own application to set the camera's control and status registers
(CSRs).
With the CCT+
With the CCT+ (see Section 4.1), you use the AOI Starting Pixel parameter and the AOI Length
parameter in the AOI parameters group to set the AOI.
By Setting CSRs
You set the AOI starting pixel by writing a value to the Starting Pixel field of the AOI Starting Pixel
CSR (see page 4-34).
You set the AOI length by writing a value to the Length field of the AOI Length CSR (see page
35).
See Section
4.2.2
The AOI Starting Pixel must be set to an odd number and the AOI Length must be set
to an even number.
In normal operation, the camera is set to use all of the pixels in the array. To use all
of the pixels, the starting pixel should be set to 1 and the length in pixels to 8160.
See Section
and the stamp feature are both enabled.
BASLER L800
k
Draft
explains CSRs and Section
3.8
for information about how the camera will operate if the AOI feature
4.3.1
explains using read/write commands.
Operation and Features
4-
3-19