A-10-2 Functions That Were Added Or Changed For Each Unit Version - Omron NXEIP202 User Manual

Machine automation controller
Table of Contents

Advertisement

Appendices
A-10-2
Functions That Were Added or Changed for Each Unit Version
This section gives the functions that were added or changed for each unit version of the EtherNet/IP
Coupler Unit.
Changes in and Additions to Functions
The following table shows the unit version of the EtherNet/IP Coupler Unit, the unit version of the CPU
Unit, the unit version of the Industrial PC, and the version of the Support Software for changes in or
additions to the functions. You can use the added or changed functions with the versions/unit versions
given in the table or with later/higher versions.
Refer to version-related information given in the user's manuals of the CPU Unit or Industrial PC for
corresponding versions when using CPU Unit versions, Industrial PC unit versions, and Support Soft-
ware versions that are the same or that are later or higher than the corresponding versions.
Depending on the type and model of the Unit, some Units do not have all of the versions given in the
corresponding versions. If a Unit does not have the specified version, support is provided by the oldest
available version after the specified version. Refer to the user's manuals for the specific Units for the
relation between models and versions.
 NX-EIC202
The following table shows the relationship when the NJ/NX-series CPU Unit is connected.
Function
NX Unit control with CIP objects
Setting IO-Link devices from Support
Software other than the Sysmac Stu-
dio connected to peripheral USB port
on the EtherNet/IP Coupler Unit
Communications Interface Unit control Addition
BOOTP client
The following table shows the relationship when the NY-series Industrial PC is connected.
Function
NX Unit control with CIP objects
Setting IO-Link devices from Support
Software other than the Sysmac Stu-
dio connected to peripheral USB port
on the EtherNet/IP Coupler Unit
Communications Interface Unit control Addition
BOOTP client
The following table shows the relationship when the CS1G/CS1H/CJ1H/CJ1M CPU Unit is con-
nected.
A - 70
Ether-
Change
Using an NX-series
Net/IP
or addi-
Coupler
tion
Unit
CPU Unit
Addition
Ver.1.2
Ver.1.14
Addition
Not possi-
ble.
Ver.1.14
Addition
Ether-
Change
Net/IP
Using an NY-series Industrial PC
or addi-
Coupler
tion
Industrial PC
Unit
Addition
Ver.1.2
Ver.1.14
Addition
Not possible.
Ver.1.14
Addition
Corresponding unit version/version
Using an NJ-series
CPU Unit
CPU Unit
Sysmac
CPU Unit
Studio
Ver.1.19
Ver.1.14
Not possi-
Not possi-
ble.
ble.
Ver.1.19
Ver.1.14
Corresponding unit version/version
Sysmac Studio
Ver.1.19
Not possible.
Ver.1.19
NX-series EtherNet/IP Coupler Unit User's Manual (W536)
NX
Unit
restric-
Sysmac
tions
Studio
Ver.1.19
None
Not possi-
Yes
ble.
Ver.1.19
Yes
None
NX Unit
restrictions
None
Yes
Yes
None