Specifications; General Specifications Of Ethernet/Ip Slave Terminals - Omron NXEIP202 User Manual

Machine automation controller
Table of Contents

Advertisement

3 Specifications and Application Procedures
3-1

Specifications

This section provides the general specifications of an EtherNet/IP Slave Terminal and the specifications
of the EtherNet/IP Coupler Unit and End Cover.
3-1-1

General Specifications of EtherNet/IP Slave Terminals

Item
Enclosure
Grounding method
Ambient operating
temperature
Ambient operating
humidity
Atmosphere
Ambient storage
temperature
Altitude
Pollution degree
Operat-
Noise immunity
ing envi-
Overvoltage cate-
ronment
gory
EMC immunity
level
Vibration resis-
tance
Shock resistance
Applicable standards
*1. Refer to the NX-series Digital I/O Units User's Manual (Cat. No. W521) for the vibration and shock resistance
specifications of the Relay Output Unit.
*2. Refer to the OMRON website (http://www.ia.omron.com/) or consult your OMRON representative for the most
recent applicable standards for each model.
3 - 2
Mounted in a panel
Ground to 100 Ω or less.
0 to 55°C
10% to 95% (with no condensation or icing)
Must be free from corrosive gases.
−25 to 70°C (with no condensation or icing)
2,000 m max.
2 or less: Conforms to JIS B3502 and IEC 61131-2.
2 kV on power supply line (Conforms to IEC61000-4-4.)
Category II: Conforms to JIS B3502 and IEC 61131-2.
Zone B
Conforms to IEC 60068-2-6.
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, acceleration of 9.8 m/s
100 min each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min
*1
total)
Conforms to IEC 60068-2-27. 147 m/s
*1
tions
cULus: Listed UL508 and ANSI/ISA 12.12.01
*2
EC: EN 61131-2
C-Tick or RCM, KC: KC Registration, and NK
Specification
2
, 3 times each in X, Y, and Z direc-
NX-series EtherNet/IP Coupler Unit User's Manual (W536)