[Network Setup]; [Network Control] - Panasonic PT-MZ10K Operating Instructions Manual

Hide thumbs Also See for PT-MZ10K:
Table of Contents

Advertisement

[SIGNAL QUALITY]

[NETWORK SETUP]

Perform the initial setting of the network before using the network function.
1)
Press as to select [NETWORK SETUP].
2)
Press the <ENTER> button.
f The [NETWORK SETUP] screen is displayed.
3)
Press as to select an item, and change the settings according to the operation instructions of the
menu.
[PROJECTOR NAME]
[DHCP]
[IP ADDRESS]
[SUBNET MASK]
[DEFAULT GATEWAY]
4)
Press as to select [STORE], and press the <ENTER> button.
f The confirmation screen is displayed.
5)
Press qw to select [OK], and press the <ENTER> button.
Note
f When using a DHCP server, confirm that the DHCP server is running.
f Consult your network administrator regarding the IP address, subnet mask, and default gateway.
f The network setting is common for the <LAN> terminal and the <DIGITAL LINK> terminal.
f [NETWORK SETUP] cannot be selected when the [NETWORK] menu → [Art-Net SETUP] is set to [ON(2.X.X.X)] or [ON(10.X.X.X)].

[NETWORK CONTROL]

Set up the control method of the network.
1)
Press as to select [NETWORK CONTROL].
2)
Press the <ENTER> button.
f The [NETWORK CONTROL] screen is displayed.
3)
Press as to select an item, and press qw to change the setting.
[WEB CONTROL]
[PJLink CONTROL]
[PJLink NOTIFICATION]
[COMMAND CONTROL]
[COMMAND PORT]
[Crestron Connected(TM)]
158 - ENGLISH
Chapter 4 Settings — [NETWORK] menu
[SIGNAL QUALITY] is a numerical value of the amount of error, and the display color changes to
green, yellow, or red depending on that value.
Check the signal quality level while receiving a signal from the twisted-pair-cable transmitter.
f [MAX]/[MIN]: Maximum/minimum value of the amount of error
f Green (-12 dB or lower) → normal signal quality level.
f Yellow (-11 to -8 dB) → caution level that noise may appear on the screen.
f Red (-7 dB or higher) → abnormal level with interrupted synchronization and receiving not
possible.
Allows to change the projector name. Enter the host name if it is required to use a DHCP server.
[ON]
[OFF]
Enter the IP address when a DHCP server is not used.
Enter the subnet mask when a DHCP server is not used.
Enter the default gateway address when a DHCP server is not used.
Set to [ON] to control with the web browser.
Set to [ON] to control with the PJLink protocol.
Set to [ON] to use the PJLink notification function.
f The [PJLink NOTIFICATION] screen is displayed when set to [ON] and the <ENTER> button is
pressed. Set the IP address of the computer to notify the status of the projector in [NOTIFIED IP
ADDRESS 1], [NOTIFIED IP ADDRESS 2].
Set to [ON] to control with the <SERIAL/MULTI PROJECTOR SYNC IN>/<SERIAL/MULTI
PROJECTOR SYNC OUT> terminal control command format (x page 229). Refer to "Control
commands via LAN" (x page 222).
Set the port number used for command control.
Set to [ON] to control with Crestron Connected of Crestron Electronics, Inc.
If a DHCP server exists in the network where the projector is to be
connected, obtains the IP address automatically.
If a DHCP server does not exist in the network where the projector
is to be connected, set [IP ADDRESS], [SUBNET MASK], and
[DEFAULT GATEWAY].