Print Messages After
Specified number of messages
500 messages or timeout period,
whichever is first
Specified number of messages or timeout
period, whichever is first.
Publication 2711PC-UM001A-EN-P - March 2009
• The advanced settings for printing diagnostic and alarm
messages determines when to print messages that are sent to
the network or USB port.
Default Value
Example
60 messages
When the queue has 60 messages, the messages are printed
regardless of how long they have been in the queue.
You can change the number of messages.
168 hours (7 days)
If the queue has 350 messages after 168 hours, the 350
messages are printed.
You can change the timeout period.
60 messages
If the queue has 60 messages after 24 hours, then the 60
168 hours (7 days)
messages are printed.
You can change the number of messages and the timeout
period.
For example, the number of messages is set to 75 and the
timeout period is set to 48 hours.
• If the queue has 75 messages after 24 hours, then the 75
• If the queue has 15 messages after 48 hours, the 15
4. Press OK when done.
5. Press OK to return to Terminal Settings.
Configuring the Terminal
messages are printed before the set timeout of 48 hours.
messages are printed after the set timeout period.
Chapter 4
59