Mounting

16
6
Mounting
6.1

Mounting requirements

No special measures such as supports are necessary. External forces are absorbed by the construction
of the device.
6.1.1

Mounting position

Mounting location
Orientation
The direction of the arrow on the sensor helps you to install the sensor according to the flow direction
(direction of medium flow through the piping).
• Install the measuring device in a parallel plane free of external mechanical stress.
• The internal diameter of the pipe must match the internal diameter of the sensor: see the
"Technical Information" device document, "Design and dimensions" section.
A
Vertical orientation
B
Horizontal orientation, transmitter head
up *
Orientation
Proline Prosonic Flow B 200 HART
Compact version
A0015545
A0015589
Endress+Hauser
A0015543
A0015895