Ultrasonic flow measuring system
Hide thumbs Also See for HART Proline Prosonic Flow B 200:
Table of Contents

Advertisement

Proline Prosonic Flow B 200 HART
Process connections
Endress+Hauser
Electrical connection
Cable gland M20 × 1.5
Cable gland M12 × 1.5
Electrical connection
Cable gland M20 × 1.5
Cable gland M12 × 1.5
Sensor housing
Stainless steel (cold worked):
– 1.4404/316L
– 1.4435/316L
Process connections
• Stainless steel:
– 1.4301/304
– 1.4306/304L
– 1.4404/316L
• Steel S235JR
• Carbon steel A105
List of all available process connections (® ä 103)
Seals
• Transducer: HNBR
• Temperature sensor: AFM 34
Accessories
Replacement tool
• Knurled handle: aluminum
• Stop cock: nickel-plated brass
• Shaft: brass
• Tensioning element: tempered steel
Flow conditioner
Stainless steel 1.4404/316L (in compliance with NACE MR0175-2003 and MR0103-2003)
Weather protection cover
Stainless steel 1.4301
Flanges:
– EN 1092-1 (DIN 2501)
– ASME B16.5
For information on the materials of the process connections (® ä 103)
For the transmitter neck
Sensor version
Two-path
Single-path
For the sensor
Sensor version
Two-path
Single-path
Technical data
Material
Stainless steel 1.4305
Material
Stainless steel 1.4305