Lateral Motorized Flap (Sml) - Access RPSP Installation Manual

Supra linea inclined platform lift
Table of Contents

Advertisement

Installation Manual – RPSP

5.8 Lateral Motorized Flap (SML)

It is possible, if necessary, to remove this device and reassemble to facilitate disconnecting the drive unit
from the mainframe. To do so, first loosen the nut detail 2 and remove the end from the actuator and replace
the nut.
Loosen the 4 screws (detail 20) and remove the crossbeam (detail 16).
It will be possible to carry out inverse operations after having assembled the machine.
Attention! Check that detail 5 of Fig. 70 does not turn. Verify that stop micro insertion is working
regularly and without mechanical piece interference.
Attention! When the platform and flap are completely open, the cable is completely elongated. In
this configuration it is possible to work on the device by removing it. Replace the platform and flap in
this configuration before electrically controlling the device.
Attention! Do not close the platform manually when the flap is lifted in the drive position. When the
platform closes, the traction cable is pulled and the actuator, if not properly elongated, could
become damaged.
Fig. 70 – Detail of Lateral motorized flap