Wiring Outside The Inclined Platform Lift; Wiring; Guide Casing Fastening - Access RPSP Installation Manual

Supra linea inclined platform lift
Table of Contents

Advertisement

Installation Manual – RPSP

4.3 Wiring outside the Inclined Platform Lift

4.3.1 Wiring

 The long length of cable coming out of the chain (3G1,5
mm
power cable) must be laid in the appropriate space on
2
the surface of the guide casing and this must then be
inserted into the appropriate slot as shown in figure 1. The
stop between these two components is snap-on.
 Use the appropriate space between the closure bung and
the guide to pass through the corrugated pipe for external
supply. The corrugated pipe has to be fitted over the proper
placing. This caution prevents water infiltrations inside the
corrugated in case of outdoor installations
 Make the following connections on the machine:
o Single-phase version: insert the clamp marked M1 of the chain cable in to the M1 clamp fitted on the
PowerBoard D-142-1.
o Three-phase: insert the M1 marked clamp of the chain cable in to the M1 clamp of the access
terminal board.
 In the Electric Box connect the wires 1 and 2 after the magneto-thermic.
 Connect the yellow-green coloured wire to the ground clamp.

4.3.2 Guide Casing fastening

 The plastic caps must be mounted using the special brass
inserts to be entered by the means of a mallet.
 Use the cylinder head screws (provided from the factory) to
attach themselves to the guide.
 During normal machine operation, vibrations may cause the
guide hood to lower. For this reason, the use of self-
supporting 4.8x50 screws is recommended to lock the
hood.
These screws must be positioned at the lowest end of the
guide.
Procedure is as follows:
1. Make a hole with a 4mm drill point at approximately 8 mm from the hood edge (using the "v" marks
shown on the profile).
2. Flare the visible part of the hood
3. Insert the supplied self-supporting screws
4. Insert the plastic guide caps
Attention! When all above-indicated directions regarding hole positioning have been followed, guide
caps will overlap the screws which have just been inserted.
Fig. 38 – Wiring
Fig. 39 – Hood fastening points
32
INS-RPSP-EN-05

Advertisement

Table of Contents
loading

Table of Contents