Access RPSP Installation Manual page 21

Supra linea inclined platform lift
Table of Contents

Advertisement

Installation Manual – RPSP
 With reference to Fig. 14 – fase1 (and
the assembly sequence shown in that
figure) fix the register to the guide by
the bushing, the M8 screw and the
special nut provided (register illustrated
in Fig. 20B, assembly in Fig. 20A).
 Tilt the register and insert the stanchion
into the register (Fig. 14 – fase2).
Check that the special nut has taken to
the stanchion and tighten by hand.
 Return the register and the stanchion to
an upright position and fix the upper
screw (with a lock-nut) and the lower
screw (with the other special nut), as
shown in Fig. 14 – fase3 e 4.
A
Fig. 20B shows the two register stanchions (standard on the left, short on the right) supplied with the
machine. The V mark indicates the top of the register. The short register is always used for the first stanchion
at the bottom. For very low angles of inclination only standard registers are used.
Fig. 19 – Stanchion assembly detail
Fig. 20 – Register detail
20
INS-RPSP-EN-05
Stanchion
(the dashed arrow
shows the direction
of insertion)
Register
in inclined position
B