Installation Kit - Special Equipment; Fastening Torques; Personal Protection Equipment - Access RPSP Installation Manual

Supra linea inclined platform lift
Table of Contents

Advertisement

Installation Manual – RPSP
3.2 Installation kit – Special equipment
For fast and efficient installation, ThyssenKrupp Encasa provides an INSTALLATION KIT that includes the
following special equipment:
 Special starter unit for power the electric motor and move
the traction unit
 Equipment for removing the guide casing.
 Handle for lifting the traction unit

3.3 Fastening torques

In order to guarantee correct machine assembly, the bolts must be fastened with the appropriate fastening
torques as given in the table below:
SCREW DIAMETER
(mm)
M5
M6
M8
M10
M12

3.4 Personal protection equipment

For the purposes of protecting staff assembling the machine, the personal protection equipment must be
used as also prescribed by current applicable law.
FASTENING
SCREW DIAMETER
TORQUE (Nm)
6
10
25
49
86
15
FASTENING
(mm)
TORQUE (Nm)
M14
136
M16
210
M18
290
M20
410
M22
550