4.1.3 Extra anchoring on top

The extra wall anchoring can be mounted after connecting all the stanchions to the guide.
The correct assembly order is as follows:
 Bring the guide to the wall (make sure
it is in the correct position)
 With a pencil mark the two ends of the
stanchion on the wall
 Take the guide away from the wall
 Remove the stanchion from its register
 Position the stanchion next to the wall
using the previously obtained
references
 Mark the drilling points
 Drill a hole for the screw anchor
 Fix the stanchion to the wall
 Remount the register onto the
stanchion (the guide is already in the
correct position)
Tip: you can also insert the stanchion into the register from the front: position the special nuts with
their long side upright and then bring the guide to the stanchion with force.
Tip: if the wall is a long way from the guide, a threaded bar can be used instead of a screw anchor.