5.2 Adjusting the stop position

The machine is equipped with two adjustable stop points. Proceed as follows before applying them. Bring
the machine to where you want it to stop. Check from the table according to the guide's angle of inclination
where the stop points should be. Move the machine away and set the stop point temporarily using only one
screw and positioning it approximately in the centre of the slot. Then make the final adjustment by moving
the machine back and forwards until the required stop point is set. At this point the cam can be locked with
the second screw.
Attention! The limit switch end with a slotted hole must be set on the opposite side of the one
coming from the position of the machine.
Caution! The stop cam may interfere with the guide fixing device.
Origin of the
machine
"V" for cam perforating
Fig. 57 – Cam mounting