A temperature warning is output to the hardware event log and OS event log,
or ServerView issues a notification of a temperature warning such as by a
popup message.
The above log is output or the above notification is issued by ServerView when the ambient temperature
is within 30 to 35 °C, which is near the upper limit of the temperature boundaries (10 to 35 °C). This is
to notify the administrator before the ambient temperature actually exceeds the range of the temperature
boundaries.
Although continued use within the temperature boundaries poses no problems within itself, reconsider
the surrounding environment conditions if this log is output or if ServerView issues this notification.
POST stops, generating the "Expansion ROM not initialized..." message.
Change [Reset Configuration Data] on "8.2.5 Advanced Menu" ( pg.230) to [Yes] in the BIOS Setup
Utility.
The server does not recognize the connected RS-232C device.
Check that Serial Port 1 is configured as a server management port.
Serial Port 1 can be used as a server management port on this server; however, it cannot be connected to
an RS-232C device.
For how to use the server management port, refer to "Appendix C Using the Server Management Port"
( pg.299).
Serial ports are not recognized properly in Device Manager.
This may occur when the Serial 1 and Serial 2 settings are changed with "8.2.6 Peripheral Configuration
Submenu" ( pg.231) in the [Advanced] menu of the BIOS Setup Utility. If this occurs, delete all serial
ports in Device Manager and restart the system.
■ Display
The display does not power on.
Check to see whether the power cable of the display is properly connected to the outlet. For details, refer
to "Start Guide" or the manual of the display.
Nothing is displayed on the screen.
• Check to see whether the display cable is connected properly.
If it is not connected, turn the server off and then connect the cable. For the connection location, refer
to "Start Guide".
• Check that the brightness volume and contrast volume of the display are adjusted correctly. If they
need to be adjusted, perform the necessary adjustments.
For details, refer to the manual of the display.
• There may be an error in the system area of the memory. Contact an office listed in the "Contact