Lanview Leds - Enterasys Matrix 7G4282-41 Hardware Installation Manual

Dfe-platinum series
Hide thumbs Also See for Matrix 7G4282-41:
Table of Contents

Advertisement

Table
4‐2 describes the LED indications and provides recommended actions as 
appropriate.
The terms flashing, blinking, and solid used in
Flashing indicates an LED is flashing randomly.
Blinking indicates an LED is flashing at a steady rate (approximately 50% on, 50%
off).
Solid indicates a steady LED light. No pulsing.
Alternating indicates an LED is flashing in a steady rate other than 50% on, 50%
off.
Table 4-2 LANVIEW LEDs
LED
Color
MGMT
None
Green
Amber
CPU
None
Amber
Green
Red
Green
and
Amber
State
Off. This module is NOT the
Management Module.
Solid. This module is the
designated Management
Module.
Flashing. This is a
temporary indication that the
module is saving data.
Power off.
Blinking. Module in process
of booting.
Solid. Testing.
Blinking. Image starts
running.
Solid. Functional.
Solid. Processor in reset.
Blinking. Indicates that the
module is in the process of
shutting down.
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide
Table 4-2
indicate the following:
Recommended Action
None.
None.
None.
Ensure chassis has adequate power.
None.
If the LED remains amber for several
minutes, contact Enterasys Networks
for technical support.
None.
None.
None.
None. This state is activated when the
OFFLINE/RESET switch is pressed for
less than 1 second to a start the process
of an orderly shutdown.
While in this state, do not remove any
DFE-Platinum module.
Using LANVIEW
4-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Matrix 7g4202-60

Table of Contents