Last Resort Shutdown Procedure Using Offline/Reset Switch - Enterasys Matrix 7G4282-41 Hardware Installation Manual

Dfe-platinum series
Hide thumbs Also See for Matrix 7G4282-41:
Table of Contents

Advertisement

Overview of DFE-Platinum Module Shutdown Procedure
Its CPU LED changes from solid green to blinking between green and amber, indicating 
that the module is shutting down. At the end of the shutdown routine, the CPU LED 
changes to a 67%/33% sequence of amber/off, respectively, indicating the module is in a 
halt state. In this time it is safe to restart or remove the module from the chassis.
When a controlled shutdown is initiated from the 
seconds from the time the CPU starts alternately flashing amber/off until the device 
automatically restarts.

Last Resort Shutdown Procedure Using OFFLINE/RESET Switch

To reset a DFE‐Platinum module without it performing an orderly shutdown routine, 
press and hold the OFFLINE/RESET switch for approximately 6 seconds. 
Pulling any DFE‐Platinum module out of the chassis before it has been shut down is not 
recommended. The only safe time to pull a module out of the chassis is after the 
completion of a shutdown and the management LED is alternately flashing amber/off.
4-8
Troubleshooting
Note: The only safe time to pull a DFE-Platinum module out of the chassis is when the
CPU LED is alternately flashing amber/off. Otherwise, system operation will be
interrupted.
Caution: This method of shutting down a DFE-Platinum module is not recommended
except as a last resort, because all processes currently running on the module will be
interrupted resulting in loss of frames.
Precaución: No se recomienda utilizar este método para apagar los módulos DFE- Gold.
Recurra a él sólo como último recurso, puesto que interrumpe todos los procesos del
módulo en funcionamiento, lo que podría resultar pérdidas de frames.
OFFLINE/RESET switch