This chapter provides information concerning the following:
"Using LANVIEW" on page 4‐1
"Troubleshooting Checklist" on page 4‐5
"Overview of DFE‐Platinum Module Shutdown Procedure" on page 4‐6
Unless otherwise noted, the following information applies to all DFE modules.

USING LANVIEW

The modules use a built‐in visual diagnostic and status monitoring system called 
LANVIEW. The LANVIEW LEDs (Figure
status to aid in diagnosing network problems. 
About the Management (MGMT) LED
The MGMT LED (shown in Figure
Management Module to control the management functions for all DFE‐Platinum modules 
in the chassis. The Management Module handles all IP requests to the chassis IP address, 
such as PING, Telnet, SNMP, HTTP, etc. The Management Module also handles the CLI 
configuration sessions via the console port. So, when you plug into a DFE‐Platinum 
module COM port to configure a module in the chassis, it is handled by the Management 
Module regardless of the DFE‐Platinum module COM port that you use. 
Viewing the Receive and Transmit Activity
On the 7G4202‐60 and 7G4282‐41, you can view the receive and transmit activity on the 
RX and TX LEDs. However, only one group of ports may be viewed at a time. On the 
7G4282‐41, there are 8 ports per group. On the 7G4202‐60, there are 20 ports per group.
"Recommended Shutdown Procedure Using OFFLINE/RESET Switch" on 
page 4‐7
"Last Resort Shutdown Procedure Using OFFLINE/RESET Switch" on page 4‐8
4‐1) allow quick observation of the network 
4‐1) indicates when the module is serving as the 