Using LANVIEW
Table 4-2 LANVIEW LEDs (Continued)
LED
RX
(Receive)
TX
(Transmit)
4-4
Troubleshooting
Color
State
Amber
Alternating (67% on, 33%
and off
off). Indicates that a
shutdown process has
completed. This indication
will remain for 60 seconds
before automatically
restarting.
None
No link. No activity. Port
enabled or disabled.
Green
Solid. Link present, port
enabled, no traffic is being
received by the interface.
Amber
Flashing. Link present, port
enabled, traffic is being
received by the interface.
Red
Blinking. Indicates
collisions. This indication is
only supported on 10/100
ports.
None
Port enabled, but no activity.
Green
Flashing. Indicates data
transmission activity. Rate of
flashing indicates the data
rate.
Red
Flashing. Fault or Error
(collision).
Recommended Action
While in this state, you have 60 seconds
to safely remove the DFE-Platinum
module from the chassis.
None.
None.
None.
Contact Enterasys Networks for
technical support.
If it is known that the port should be
active and is not, contact Enterasys
Networks for technical support.
None.
None, unless there is a high rate of
activity. In this case, check for network
configuration problems or a defective
device.