Technical data

13.
Technical data
Information
13.1.

Technical data Multi-turn actuators

Features and functions
Explosion protection
Certificates and standards
Particular conditions of use
Type of duty
(Multi-turn actuators for open-close
duty)
Type of duty
(Multi-turn actuators for modulating
duty)
Motors
Mains voltage, mains frequency
Overvoltage category
Insulation class
Motor protection
Self-locking
Motor heater (option)
Manual operation
Indication for manual operation (op-
tion)
Electrical connection
Threads for cable entries
Terminal plan
82
SAVEx 07.2
SAVEx16.2/SARVEx 07.2
The following tables include standard and optional features. For detailed information
on the customer-specific version, refer to the order-related data sheet. The technical
data sheet can be downloaded from the Internet in both German and English at ht-
tp://www.auma.com (please state the order number).
Refer to name plate
Certificates are attached to the device. All standards applied and their respective issues are indicated
on these certificates.
The particular conditions of use are listed on the certificates supplied.
Standard:
Short-time duty S2 - 15 min, classes A and B according to EN 15714-2
Option:
Short-time duty S2 - 30 min, classes A and B according to EN 15714-2
For 100 % nominal voltage and +40 °C ambient temperature and at run torque load at maximum output
speed.
Standard:
Intermittent duty S4 - 25 %, class C according to EN 15714-2
Option:
Intermittent duty S4 - 50 %, class C according to EN 15714-2
For 100 % nominal voltage and +40 °C ambient temperature and at modulating torque load.
3-phase AC asynchronous motor, type IM B9 according to IEC 60034-7, IC410 cooling procedure ac-
cording to IEC 60034-6
Refer to name plate of ACV actuator controls
Permissible variation of mains voltage: ±10 %
Permissible variation of mains frequency: ±5 %
Category III according to IEC 60364-4-443
Standard:
F, tropicalized
Option:
H, tropicalized
Standard:
PTC thermistors (according to DIN 44082)
Self-locking: Speed ranges 6
NOT self-locking: Speed range variant 24
Multi-turn actuators are self-locking if the valve position cannot be changed from standstill while torque
acts upon the output drive.
Voltages:
110
120 V AC, 220
Power depending on the size 12.5
Manual drive for setting and emergency operation, handwheel does not rotate during electrical operation.
Option:
Handwheel lockable
Handwheel stem extension
Power tool for emergency operation with square 30 mm or 50 mm
Indication whether manual operation is active/not active via single switch (1 change-over contact)
Standard:
AUMA Ex plug/socket connector with screw-type terminals (KP)
Option:
Ex plug/socket connector with terminal blocks (KES), increased safety Ex e
Ex plug/socket connector with terminal blocks (KES), flameproof enclosure Ex d
Ex plug/socket connector KT/KM, increased safety Ex e
Ex plug/socket connector KT/KM, flameproof enclosure Ex d
Standard:
Metric threads
Option:
Pg-threads, NPT-threads, G-threads
Terminal plan according to order number enclosed with delivery
SARVEx16.2 Control unit: electronic (MWG)
60 rpm and 12
108 rpm
216 rpm
240 V AC or 380
480 V AC
25 W
ACVExC 01.2 Non-Intrusive