SAVEx 07.2
SAVEx16.2/SARVEx 07.2
ACVExC 01.2 Non-Intrusive
Service conditions
Use
Mounting position
Installation altitude
Ambient temperature
Humidity
Enclosure protection in accordance
with IEC 60529
Pollution degree according to
IEC 60664-1
Vibration resistance according to
IEC 60068-2-6
Corrosion protection
Coating
Colour
Accessories
Wall bracket
Programming software
Further information
Weight
EU Directives
Reference documents
SARVEx16.2 Control unit: electronic (MWG)
Indoor and outdoor use permissible
Any position
≤ 2 000 m above sea level
> 2,000 m above sea level on request
Refer to name plate of actuator controls
Up to 100 % relative humidity across the entire permissible temperature range
IP68
Terminal compartment additionally sealed against interior (double sealed)
According to AUMA definition, enclosure protection IP68 meets the following requirements:
Depth of water: maximum 8 m head of water
Continuous immersion in water: maximal 96 hours
Up to 10 operations during immersion
Modulating duty is not possible during immersion.
For exact version, refer to actuator controls name plate.
Pollution degree 4 (when closed), pollution degree 2 (internal)
1 g, from 10 Hz to 200 Hz
Resistant to vibration during start-up or for failures of the plant. However, a fatigue strength may not be
derived from this. (Not valid in combination with gearboxes)
Standard:
KS: Suitable for use in areas with high salinity, almost permanent condensation, and high
pollution.
Option:
KX: Suitable for use in areas with extremely high salinity, permanent condensation, and
high pollution.
Double layer powder coating
Two-component iron-mica combination
Standard:
AUMA silver-grey (similar to RAL 7037)
Option:
Available colours on request
For actuator controls mounted separately from the actuator, including plug/socket connector. Connecting
cable on request.
Recommended for high ambient temperatures, difficult access, or in case of heavy vibration during
service.
Cable length between actuator and actuator controls is max. 16 m. Longer cables require an external
filter (filter available on request).
AUMA CDT (Commissioning and Diagnostic Tool for Windows-based PC)
AUMA Assistant App (Commissioning and Diagnostic Tool)
Approx. 12 kg (with AUMA KT Ex plug/socket connector)
ATEX Directive 2014/34/EU
Machinery Directive 2006/42/EC
Low Voltage Directive 2014/35/EU
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
RED Directive 2014/53/EU
Dimensions SAVEx 07.2
SAVEx 16.2/SARVEx 07.2
Dimensions SQVEx 05.2
SQVEx 14.2/SQRVEx 07.2
Electrical data SAVEx 07.2
SAVEx 16.2/SARVEx 07.2
Electrical data SQVEx 05.2
SQVEx 14.2/SQRVEx 05.2
Technical data
SARVEx 16.2 with ACVExC 01.2
SQRVEx 16.2 with ACVExC 01.2
SARVEx 16.2
SQRVEx 14.2
87