Configuring the Trap Table
SDLC Rem. Link Stn Not Responding
Self-explanatory. (Rem Link Stn is the Remote Link Station.)
Severity
Action
SDLC Link Stn Sent DM
The link station sent a Disconnect Mode response, and the logical link is down.
Severity
SDLC Link Stn rcvd FRMR, Inv. cmd
The remote device received an invalid command and responded with a Frame
Reject.
Severity
SDLC Stn rcvd FRMR, IFLD invalid
The remote device received an unpermitted I frame and responded with a Frame
Reject.
Severity
SDLC Stn rcvd FRMR, Nr invalid
The remote device received a frame with an invalid N
Frame Reject.
Severity
SDLC Stn rcvd FRMR, Ifld too long
The remote device received an I frame that was too long and responded with a
Frame Reject.
Severity
SDLC Rem Stn sent Invalid Command
The remote device received an invalid or unsupported command.
Severity
SDLC Rem Stn sent unexpected IFLD
The remote device send an unpermitted I frame.
Severity
SDLC Rem Stn sent invalid Nr
The remote device sent a frame with an invalid N
Severity
3-26
Major (Level 2)
Check the PU to make sure it is operational.
Major (Level 2)
Major (Level 2)
Major (Level 2)
Major (Level 2)
Major (Level 2)
Major (Level 2)
Major (Level 2)
Major (Level 2)
and responded with a
(r)
.
(r)
Trap Messages
701
702
704
705
706
707
708
709
710