Cabletron Systems SPECTRUM 1800 User Manual page 58

Portable management application for the frx4000, frx6000, and smartswitch 1800
Hide thumbs Also See for SPECTRUM 1800:
Table of Contents

Advertisement

Configuring the Trap Table
Trn Port Usage exceeded T: "n" C: "n"
The port statistic % Transmit Port Utilization has exceeded the threshold (T: ÒnÓ)
that was set by the user. (C: ÒnÓ is the current value.)
Severity
Action
Receive Yellow Alarm Condition Set
A Yellow Alarm was received.
Severity
Action
Receive Yellow Alarm Condition Set
The condition that caused event 338 has been cleared
Severity
LIC "n" Installed, Not Configured
The speciÞed Line Interface Card (LIC) exists in the node, but has not been
conÞgured in the Line Processor Þle.
Severity
Action
LIC "n" Configured, Not Installed
The speciÞed Line Interface Card (LIC) has been conÞgured in the Line Processor
Þle, but does not exist in the node.
Severity
Action
LIC "n" Config Mismatch—Type "n"
The interface type of the speciÞed Line Interface Card (LIC) installed in the node
is different from the interface type conÞgured in the Line Processor Þle. As a
result, the software does not load properly and will not operate.
Severity
Action
Link Enabled
The port has been enabled from the On-Line Port Operations menu.
Severity
3-8
Informational (Level 4)
If this happens frequently, you may need to add ports or reroute
some trafÞc.
Major (Level 2)
Contact your T1 carrier.
Informational (Level 4)
Minor (Level 3)
ConÞgure the LIC or remove it from the node.
Critical (Level 1)
Install the LIC or delete its record.
Major (Level 2)
Change either the card or the Þle.
Major (Level 2)
319
338
339
377
378
379
400
Trap Messages