Configuring the Trap Table
Duplicate of DLCI "n" on Port
Each connection sharing a DLCI must be on a different logical port, and two
records have been conÞgured in the FRX specifying the same logical port on one
DLCI. (DLCIs are conÞgured in records for logical ports, IP/LLC2/IPX interfaces
over frame relay, and frame relay PVCs.) Only one of the duplicate connections
will come up.
Severity
Action
File Update: FRDLCI.DAT
The Frame Relay DLCI conÞguration Þle has been updated.
Severity
Received Port Disable Request
Self-explanatory.
Severity
Action
Received Port Dump Request
The BSC device has experienced a problem that caused it to send a request to send
a dump to the port.
Severity
Action
Node Under Remote Control
Self-explanatory.
Severity
Remote Control Released
Self-explanatory.
Severity
Remote Control CXN Clr cc= "n" dc = "n"
A remote control connection was cleared.
Severity
Action
3-12
Minor (Level 3)
Check the database records for the duplicate conÞguration and
change one (or more) of the records.
Informational (Level 4)
Critical (Level 1)
None; however, all users of this port should be made aware of the
disable.
Critical (Level 1)
Check the device.
Informational (Level 4)
Informational (Level 4)
Informational (Level 4)
Depends on the cause.