Receive Loss of Sync condition Set
The receiving end of the connection has reported a loss of synchronization.
Severity
Action
Receive Carrier Loss condition Set
The receiving end of the connection has reported that the signal from the carrier is
lost.
Severity
Action
Receive Remote Alarm condition Set
The remote device is not receiving the signal from the local device.
Severity
Action
Receive Loss of Sync condition Cleared
The situation that caused event 650 has been Þxed. However, the T1/E1
connection will not be operational if any of events 650-652 have been set but not
cleared.
Severity
Receive Carrier Loss condition Cleared
The situation that caused event 651 has been Þxed. However, the T1/E1
connection will not be operational if any of events 650-652 have been set but not
cleared.
Severity
Receive Remote Alarm condition Cleared
The situation that caused event 652 has been Þxed. However, the T1/E1
connection will not be operational if any of events 650-652 have been set but not
cleared.
Severity
Trap Messages
Major (Level 2)
Check the T1/E1 cable at the local end of the connection. If it is
securely connected and everything else appears operational,
contact your carrier.
Major (Level 2)
Check the T1/E1 cable at the local end of the connection. If it is
securely connected and everything else appears operational,
contact your carrier.
Major (Level 2)
Check the T1/E1 cable at the local end of the connection. If it is
securely connected and everything else appears operational,
contact your carrier.
Informational (Level 4)
Informational (Level 4)
Informational (Level 4)
Configuring the Trap Table
650
651
652
653
654
655
3-25