Configuring the Trap Table
Exit Service Affecting Condition
The situation that caused event 362 has ended.
Severity
DLCI "n" Frm Relay PVC Disconnected
Self-explanatory.
Severity
DLCI "n" Received Bad Frame
Either the DLCI was not conÞgured or the frame was on an unavailable DLCI.
Severity
Action
DLCI "n" No Response to STATUS ENQ
There was no response to a status enquiry from the DTE.
Severity
Action
DLCI "n" Flow Control On
Flow control has been implemented on a frame relay port and data is queued.
Severity
DLCI "n" Frame Discarded—Flow Ctl
Self-explanatory.
Severity
Action
DLCI "n" Line does not exist
Self-explanatory.
Severity
Action
DLCI "n" Not Configured
Self-explanatory.
Severity
Action
3-22
Major (Level 2)
Informational (Level 4)
Minor (Level 3)
ConÞgure the DLCI or resent the frame.
Minor (Level 3)
Check the status of the DCE.
Minor (Level 3)
Minor (Level 3)
The frame must be resent.
Minor (Level 3)
Check the conÞguration records for the node, LP and port.
Minor (Level 3)
ConÞgure the DLCI in the portÕs database record.