Cabletron Systems SPECTRUM 1800 User Manual page 56

Portable management application for the frx4000, frx6000, and smartswitch 1800
Hide thumbs Also See for SPECTRUM 1800:
Table of Contents

Advertisement

Configuring the Trap Table
LP Trn Frm/Sec exceeded T: "n" C: "n"
The RLP statistic Transmitted Frames/Sec has exceeded the threshold (T: ÒnÓ)
that was set by the user. (C: ÒnÓ is the current value.)
Severity
Action
LP Rej Frm/Sec exceeded T: "n" C: "n"
The RLP statistic Rejected Frames/Sec has exceeded the threshold (T: ÒnÓ) that
was set by the user. (C: ÒnÓ is the current value.)
Severity
Action
LP Rtrn Frm/S exceeded T: "n" C: "n"
The RLP statistic Retransmitted Frames/Sec has exceeded the threshold (T: ÒnÓ)
that was set by the user. (C: ÒnÓ is the current value.)
Severity
Action
Rcv Frm/Sec exceeded T: "n" C: "n"
The port statistic Received Frames/Sec has exceeded the threshold (T: ÒnÓ) that
was set by the user. (C: ÒnÓ is the current value.)
Severity
Action
Tran Frm/Sec exceeded T: "n" C: "n"
The port statistic Transmitted Frames/Sec has exceeded the threshold (T: ÒnÓ)
that was set by the user. (C: ÒnÓ is the current value.)
Severity
Action
RTrn Frm/Sec exceeded T: "n" C: "n"
The port statistic Retran Frames/Sec has exceeded the threshold (T: ÒnÓ) that was
set by the user. (C: ÒnÓ is the current value.)
Severity
Action
3-6
Informational (Level 4)
If this happens frequently, you may need to reroute some trafÞc.
Informational (Level 4)
If this happens frequently, check the line for noise and check for
conÞguration errors on both the FRX port and the connected user
device.
Informational (Level 4)
If this happens frequently, check the line for noise and check for
conÞguration errors on both the FRX port and the connected user
device.
Informational (Level 4)
If this happens frequently, you may need to reroute some trafÞc.
Informational (Level 4)
If this happens frequently, you may need to reroute some trafÞc.
Informational (Level 4)
If this happens frequently, check the line for noise, and check for
conÞguration errors on both the FRX port and the connected user
device.
307
308
309
311
312
313
Trap Messages